- Dimensions (mm): h: 302.5 x W: 211.5 x D: 116.5
- Weight: 2.2 kg
- Installation circuit: Max. 40A fuse on installation circuit for charging stations. The charging station must be protected by a max. 40A Type A 30mA RCD circuit breaker.
- Installation network, Voltages: TN, IT and TT 230VAC ± 10% 400VAC ± 10% 50/60 Hz
- Max. current and charging output: 22kW at 32A/3-phase (TN networks) 7.4kW at 32A/1-phase IT/TN
- Charging socket: IEC 62196-2 Type 2 Female Electronic lock, can be permanently locked by user
- Earth fault protection: RDC DC 6mA according to IEC 62955 Electronic, automatic reset by replugging Type 2 cable
- Standards and approvals: CE compliance in accordance with IEC 61851-1:2017 and IEC 62955, and the Radio Equipment Directive 2014/53/EU and ROHS Directive 2011/65/EU
- Operating Temperature: -30*C to 50*C
- Storage Temperature: -40*C to 85*C
- Degree of protection: IP54 (IP22 without cover)
- IK Rating: 1K08
- UL Rating: UL94 5VA flammability rating
- UV Resistance: YES
- Electrical protection: Protection class II (4kV AC and 6kV impulse, insulation) Overvoltage category III (4kV)
- Means of Disconnect: External branch circuit breaker
- Terminal Blocks: Single Cable: 2.5-10mm2, copper only
Oplev en problemfri købsoplevelse hos Zapp! Vi tilbyder hurtig levering på 2-4 hverdage med GLS, eller vælg selv afhentning på vores lager i Haderslev. Vores eksperter står også klar til at installere din ladeboks inden for blot 14 dage. Og hvis du ikke er helt tilfreds, kan du returnere din vare inden for 14 dage uden besvær. Vi sætter din tilfredshed i højsædet hos Zapp!
Hos Zapp gør vi det nemt at handle! Vælg mellem sikre betalingsmuligheder som kreditkort eller Mobilepay. Ønsker du at dele betalingen op, så betal med Anyday og del din betaling op i 4 rentefrie og gebyrfrie rater over 4 måneder.
Beskrivelse
Specifikationer
- Dimensions (mm): h: 302.5 x W: 211.5 x D: 116.5
- Weight: 2.2 kg
- Installation circuit: Max. 40A fuse on installation circuit for charging stations. The charging station must be protected by a max. 40A Type A 30mA RCD circuit breaker.
- Installation network, Voltages: TN, IT and TT 230VAC ± 10% 400VAC ± 10% 50/60 Hz
- Max. current and charging output: 22kW at 32A/3-phase (TN networks) 7.4kW at 32A/1-phase IT/TN
- Charging socket: IEC 62196-2 Type 2 Female Electronic lock, can be permanently locked by user
- Earth fault protection: RDC DC 6mA according to IEC 62955 Electronic, automatic reset by replugging Type 2 cable
- Standards and approvals: CE compliance in accordance with IEC 61851-1:2017 and IEC 62955, and the Radio Equipment Directive 2014/53/EU and ROHS Directive 2011/65/EU
- Operating Temperature: -30*C to 50*C
- Storage Temperature: -40*C to 85*C
- Degree of protection: IP54 (IP22 without cover)
- IK Rating: 1K08
- UL Rating: UL94 5VA flammability rating
- UV Resistance: YES
- Electrical protection: Protection class II (4kV AC and 6kV impulse, insulation) Overvoltage category III (4kV)
- Means of Disconnect: External branch circuit breaker
- Terminal Blocks: Single Cable: 2.5-10mm2, copper only